CVE search
Every published CVE plus open-source advisories (NVD, OSV, GitHub), with CVSS, EPSS and whether it is being exploited in the wild (CISA KEV). Updated every few hours. Our scans match these against the technologies they detect.
Every published CVE plus open-source advisories (NVD, OSV, GitHub), with CVSS, EPSS and whether it is being exploited in the wild (CISA KEV). Updated every few hours. Our scans match these against the technologies they detect.
Advantech WebAccess 8.4.2 and 8.4.4 allows XSS via the username column of the bwRoot.asp page of WADashboard. |
| 11/06/2021 |
| CVE-2021-27437 | CRITICAL9.1 | The affected product allows attackers to obtain sensitive information from the WISE-PaaS dashboard. The system contains a hard-coded administrator username and password that can be used to query Grafana APIs. Authentication is not required for exploitation on the WISE-PaaS/RMM (versions prior to 9.0.1). | 07/05/2021 |
| CVE-2021-22669 | HIGH8.8 | Incorrect permissions are set to default on the ‘Project Management’ page of WebAccess/SCADA portal of WebAccess/SCADA Versions 9.0.1 and prior, which may allow a low-privileged user to update an administrator’s password and login as an administrator to escalate privileges on the system. | 26/04/2021 |
| CVE-2021-27436 | MEDIUM6.1 | WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user’s cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions. | 18/03/2021 |
| CVE-2020-13554 | HIGH7.8 | An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege. | 03/03/2021 |
| CVE-2020-25161 | HIGH8.8 | The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator. | 23/02/2021 |
| CVE-2020-13555 | HIGH8.8 | An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In COM Server Application Privilege Escalation, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege. | 17/02/2021 |
| CVE-2020-13553 | HIGH8.8 | An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege. | 17/02/2021 |
| CVE-2020-13552 | HIGH8.8 | An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via multiple service executables in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYST | 17/02/2021 |
| CVE-2020-13551 | HIGH8.8 | An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via PostgreSQL executable, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege. | 17/02/2021 |
| CVE-2020-13550 | HIGH7.7 | A local file inclusion vulnerability exists in the installation functionality of Advantech WebAccess/SCADA 9.0.1. A specially crafted application can lead to information disclosure. An attacker can send an authenticated HTTP request to trigger this vulnerability. | 17/02/2021 |
| CVE-2021-22658 | CRITICAL9.8 | Advantech iView versions prior to v5.7.03.6112 are vulnerable to a SQL injection, which may allow an attacker to escalate privileges to 'Administrator'. | 11/02/2021 |
| CVE-2021-22656 | HIGH7.5 | Advantech iView versions prior to v5.7.03.6112 are vulnerable to directory traversal, which may allow an attacker to read sensitive files. | 11/02/2021 |
| CVE-2021-22654 | HIGH7.5 | Advantech iView versions prior to v5.7.03.6112 are vulnerable to a SQL injection, which may allow an unauthorized attacker to disclose information. | 11/02/2021 |
| CVE-2021-22652 | CRITICAL9.8 | Access to the Advantech iView versions prior to v5.7.03.6112 configuration are missing authentication, which may allow an unauthorized attacker to change the configuration and obtain code execution. | 11/02/2021 |
| CVE-2020-25157 | HIGH7.5 | The R-SeeNet webpage (1.5.1 through 2.4.10) suffers from SQL injection, which allows a remote attacker to invoke queries on the database and retrieve sensitive information. | 20/10/2020 |
| CVE-2020-16202 | HIGH7.8 | WebAccess Node (All versions prior to 9.0.1) has incorrect permissions set for resources used by specific services, which may allow code execution with system privileges. | 22/09/2020 |