CVE search
Every published CVE plus open-source advisories (NVD, OSV, GitHub), with CVSS, EPSS and whether it is being exploited in the wild (CISA KEV). Updated every few hours. Our scans match these against the technologies they detect.
Every published CVE plus open-source advisories (NVD, OSV, GitHub), with CVSS, EPSS and whether it is being exploited in the wild (CISA KEV). Updated every few hours. Our scans match these against the technologies they detect.
| 25/11/2022 |
| CVE-2022-29830 | CRITICAL9.1 | Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z, and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.065T allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated | 25/11/2022 |
| CVE-2022-29829 | HIGH7.5 | Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U, and MT Works2 versions from 1.100E to 1.200J allows a remo | 25/11/2022 |
| CVE-2022-29828 | HIGH7.5 | Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally. | 25/11/2022 |
| CVE-2022-29827 | HIGH7.5 | Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally. | 25/11/2022 |
| CVE-2022-29826 | HIGH7.5 | Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users ma | 25/11/2022 |
| CVE-2022-29825 | HIGH7.5 | Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users | 25/11/2022 |
| CVE-2022-25164 | HIGH7.5 | Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can | 25/11/2022 |
| CVE-2020-14496 | CRITICAL9.8 | Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tamper | 19/05/2022 |
| CVE-2020-14523 | CRITICAL9.8 | Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code. | 11/02/2022 |
| CVE-2020-14521 | CRITICAL9.8 | Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. | 11/02/2022 |
| CVE-2021-20588 | CRITICAL9.8 | Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versi | 19/02/2021 |
| CVE-2021-20587 | CRITICAL9.8 | Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 | 19/02/2021 |
| CVE-2020-5603 | HIGH7.5 | Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, G | 30/06/2020 |
| CVE-2020-5602 | HIGH7.5 | Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. | 30/06/2020 |