CVE search
Every published CVE plus open-source advisories (NVD, OSV, GitHub), with CVSS, EPSS and whether it is being exploited in the wild (CISA KEV). Updated every few hours. Our scans match these against the technologies they detect.
Every published CVE plus open-source advisories (NVD, OSV, GitHub), with CVSS, EPSS and whether it is being exploited in the wild (CISA KEV). Updated every few hours. Our scans match these against the technologies they detect.
The product does not require unique and complex passwords to be created
during installation. Using Philips's default password could jeopardize
the PACS system if the password was hacked or leaked. An attacker could
gain access to the database impacting system availability and data
integrity. |
| 18/07/2024 |
| CVE-2018-8863 | HIGH7.5 | The HTTP header in Philips EncoreAnywhere contains data an attacker may be able to use to gain sensitive information.
| 09/11/2023 |
| CVE-2021-39369 | MEDIUM6.5 | In Philips (formerly Carestream) Vue MyVue PACS through 12.2.x.x, the VideoStream function allows Path Traversal by authenticated users to access files stored outside of the web root. | 26/12/2022 |
| CVE-2021-32966 | HIGH7.5 | Philips Interoperability Solution XDS versions 2.5 through 3.11 and 2018-1 through 2021-1 are vulnerable to clear text transmission of sensitive information when configured to use LDAP via TLS and where the domain controller returns LDAP referrals, which may allow an attacker to remotely read LDAP system credentials. | 25/05/2022 |
| CVE-2021-33024 | HIGH7.5 | Philips Vue PACS versions 12.2.x.x and prior transmits or stores authentication credentials, but it uses an insecure method susceptible to unauthorized interception and/or retrieval. | 01/04/2022 |
| CVE-2021-33022 | HIGH7.5 | Philips Vue PACS versions 12.2.x.x and prior transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. | 01/04/2022 |
| CVE-2021-33020 | HIGH7.5 | Philips Vue PACS versions 12.2.x.x and prior uses a cryptographic key or password past its expiration date, which diminishes its safety significantly by increasing the timing window for cracking attacks against that key. | 01/04/2022 |
| CVE-2021-33018 | HIGH7.5 | The use of a broken or risky cryptographic algorithm in Philips Vue PACS versions 12.2.x.x and prior is an unnecessary risk that may result in the exposure of sensitive information. | 01/04/2022 |
| CVE-2021-27501 | CRITICAL9.8 | Philips Vue PACS versions 12.2.x.x and prior does not follow certain coding rules for development, which can lead to resultant weaknesses or increase the severity of the associated vulnerabilities. | 01/04/2022 |
| CVE-2021-27497 | CRITICAL9.8 | Philips Vue PACS versions 12.2.x.x and prior does not use or incorrectly uses a protection mechanism that provides sufficient defense against directed attacks against the product. | 01/04/2022 |
| CVE-2021-27493 | MEDIUM6.5 | Philips Vue PACS versions 12.2.x.x and prior does not ensure or incorrectly ensures structured messages or data are well formed and that certain security properties are met before being read from an upstream component or sent to a downstream component. | 01/04/2022 |
| CVE-2021-23173 | MEDIUM4.3 | The affected product is vulnerable to an improper access control, which may allow an authenticated user to gain unauthorized access to sensitive data. | 10/01/2022 |
| CVE-2021-43552 | MEDIUM5.5 | The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03. | 27/12/2021 |
| CVE-2021-43550 | MEDIUM6.5 | The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0. | 27/12/2021 |
| CVE-2021-43548 | MEDIUM6.5 | Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly. | 27/12/2021 |
| CVE-2021-39376 | HIGH8.8 | Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter. | 24/08/2021 |
| CVE-2021-39375 | HIGH8.8 | Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the WAdvancedFilter/getDimensionItemsByCode FilterValue parameter. | 24/08/2021 |