| CVE-2023-40256 | CRÍTICO9.8 | A vulnerability was discovered in Veritas NetBackup Snapshot Manager before 10.2.0.1 that allowed untrusted clients to interact with the RabbitMQ service. This was caused by improper validation of the client certificate due to misconfiguration of the RabbitMQ service. Exploiting this impacts the confidentiality and int | 11/08/2023 |
| CVE-2023-38404 | ALTO8.8 | The XPRTLD web application in Veritas InfoScale Operations Manager (VIOM) before 8.0.0.410 allows an authenticated attacker to upload all types of files to the server. An authenticated attacker can then execute the malicious file to perform command execution on the remote server. | 17/07/2023 |
| CVE-2023-32569 | CRÍTICO9.8 | An issue was discovered in Veritas InfoScale Operations Manager (VIOM) before 7.4.2.800 and 8.x before 8.0.410. The InfoScale VIOM web application is vulnerable to SQL Injection in some of the areas of the application. This allows attackers (who must have admin credentials) to submit arbitrary SQL commands on the back- | 10/05/2023 |
| CVE-2023-32568 | ALTO7.2 | An issue was discovered in Veritas InfoScale Operations Manager (VIOM) before 7.4.2.800 and 8.x before 8.0.410. The VIOM web application does not validate user-supplied data and appends it to OS commands and internal binaries used by the application. An attacker with root/administrator level privileges can leverage thi | 10/05/2023 |
| CVE-2023-26789 | MEDIO6.1 | Veritas NetBackUp OpsCenter Version 9.1.0.1 is vulnerable to Reflected Cross-site scripting (XSS). The Web App fails to adequately sanitize special characters. By leveraging this issue, an attacker is able to cause arbitrary HTML and JavaScript code to be executed in a user's browser. | 05/04/2023 |
| CVE-2023-28818 | MEDIO5.3 | An issue was discovered in Veritas NetBackup IT Analytics 11 before 11.2.0. The application upgrade process included unsigned files that could be exploited and result in a customer installing unauthentic components. A malicious actor could install rogue Collector executable files (aptare.jar or upgrademanager.zip) on t | 24/03/2023 |
| CVE-2023-28759 | ALTO7.8 | An issue was discovered in Veritas NetBackup before 10.0 on Windows. A vulnerability in the way the client validates the path to a DLL prior to loading may allow a lower-level user to elevate privileges and compromise the system. | 23/03/2023 |
| CVE-2023-28758 | ALTO7.1 | An issue was discovered in Veritas NetBackup before 8.3.0.2. BPCD allows an unprivileged user to specify a log file path when executing a NetBackup command. This can be used to overwrite existing NetBackup log files. | 23/03/2023 |
| CVE-2022-46414 | CRÍTICO9.8 | An issue was discovered in Veritas NetBackup Flex Scale through 3.0 and Access Appliance through 8.0.100. Unauthenticated remote command execution can occur via the management portal. | 04/12/2022 |
| CVE-2022-46413 | ALTO8.8 | An issue was discovered in Veritas NetBackup Flex Scale through 3.0 and Access Appliance through 8.0.100. Authenticated remote command execution can occur via the management portal. | 04/12/2022 |
| CVE-2022-46412 | ALTO8.8 | An issue was discovered in Veritas NetBackup Flex Scale through 3.0. A non-privileged user may escape a restricted shell and execute privileged commands. | 04/12/2022 |
| CVE-2022-46411 | ALTO8.8 | An issue was discovered in Veritas NetBackup Flex Scale through 3.0 and Access Appliance through 8.0.100. A default password is persisted after installation and may be discovered and used to escalate privileges. | 04/12/2022 |
| CVE-2022-46410 | ALTO8.8 | An issue was discovered in Veritas NetBackup Flex Scale through 3.0. An attacker with non-root privileges may escalate privileges to root by using specific commands. | 04/12/2022 |
| CVE-2022-45461 | ALTO8.8 | The Java Admin Console in Veritas NetBackup through 10.1 and related Veritas products on Linux and UNIX allows authenticated non-root users (that have been explicitly added to the auth.conf file) to execute arbitrary commands as root. | 17/11/2022 |
| CVE-2022-42308 | ALTO7.1 | An issue was discovered in Veritas NetBackup through 8.2 and related Veritas products. An attacker with local access can delete arbitrary files by leveraging a path traversal in the pbx_exchange registration code. | 03/10/2022 |
| CVE-2022-42307 | CRÍTICO9.8 | An issue was discovered in Veritas NetBackup through 10.0.0.1 and related Veritas products. The NetBackup Primary server is vulnerable to an XML External Entity (XXE) Injection attack through the DiscoveryService service. | 03/10/2022 |
| CVE-2022-42306 | MEDIO5.5 | An issue was discovered in Veritas NetBackup through 8.2 and related Veritas products. An attacker with local access can send a crafted packet to pbx_exchange during registration and cause a NULL pointer exception, effectively crashing the pbx_exchange process. | 03/10/2022 |
| CVE-2022-42305 | ALTO7.5 | An issue was discovered in Veritas NetBackup through 10.0.0.1 and related Veritas products. The NetBackup Primary server is vulnerable to a Path traversal attack through the DiscoveryService service. | 03/10/2022 |
| CVE-2022-42304 | CRÍTICO9.8 | An issue was discovered in Veritas NetBackup through 10.0 and related Veritas products. The NetBackup Primary server is vulnerable to a SQL Injection attack affecting idm, nbars, and SLP manager code. | 03/10/2022 |
| CVE-2022-42303 | CRÍTICO9.8 | An issue was discovered in Veritas NetBackup through 10.0 and related Veritas products. The NetBackup Primary server is vulnerable to a second-order SQL Injection attack affecting the NBFSMCLIENT service by leveraging CVE-2022-42302. | 03/10/2022 |