| CVE-2021-27397 | ALTO7.8 | A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context | 12/05/2021 |
| CVE-2021-27396 | ALTO7.8 | A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27398. An attacker could leverage th | 12/05/2021 |
| CVE-2021-27386 | ALTO7.5 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (Al | 12/05/2021 |
| CVE-2021-27385 | ALTO7.5 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (Al | 12/05/2021 |
| CVE-2021-27384 | CRÍTICO9.8 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (Al | 12/05/2021 |
| CVE-2021-27383 | ALTO7.5 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (Al | 12/05/2021 |
| CVE-2021-25662 | ALTO7.5 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (Al | 12/05/2021 |
| CVE-2021-25661 | ALTO7.5 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (Al | 12/05/2021 |
| CVE-2021-25660 | ALTO7.5 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (Al | 12/05/2021 |
| CVE-2021-25216 | CRÍTICO9.8 | In BIND 9.5.0 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.11.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.1 of the BIND 9.17 development branch, BIND servers are vulnerable if they are running an affected version and are configured t | 29/04/2021 |
| CVE-2021-25215 | ALTO7.5 | In BIND 9.0.0 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.9.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.11 of the BIND 9.17 development branch, when a vulnerable version of named receives a query for a record triggering the flaw des | 29/04/2021 |
| CVE-2021-25214 | MEDIO6.5 | In BIND 9.8.5 -> 9.8.8, 9.9.3 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.9.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND 9 Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.11 of the BIND 9.17 development branch, when a vulnerable version of named receives a malformed IXFR triggerin | 29/04/2021 |
| CVE-2021-31784 | ALTO7.8 | An out-of-bounds write vulnerability exists in the file-reading procedure in Open Design Alliance Drawings SDK before 2021.6 on all supported by ODA platforms in static configuration. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code ex | 26/04/2021 |
| CVE-2021-27393 | MEDIO5.3 | A vulnerability has been identified in Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2013.08), Nucleus Source Code (Versions including affected DNS modules). The DNS client does not properly randomize UDP port numbers of DNS requests. That could allow an attacker to poison the DNS cache or spoof DN | 22/04/2021 |
| CVE-2021-27392 | ALTO8.8 | A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridg | 22/04/2021 |
| CVE-2021-27389 | CRÍTICO9.8 | A vulnerability has been identified in Opcenter Quality (All versions < V12.2), QMS Automotive (All versions < V12.30). A private sign key is shipped with the product without adequate protection. | 22/04/2021 |
| CVE-2021-27382 | ALTO7.8 | A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overf | 22/04/2021 |
| CVE-2021-25678 | ALTO7.8 | A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past t | 22/04/2021 |
| CVE-2021-25677 | MEDIO5.3 | A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All ve | 22/04/2021 |
| CVE-2021-25670 | ALTO7.8 | A vulnerability has been identified in Tecnomatix RobotExpert (All versions < V16.1). Affected applications lack proper validation of user-supplied data when parsing CELL files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute c | 22/04/2021 |