| CVE-2021-43556 | ALTO7.8 | FATEK WinProladder Versions 3.30_24518 and prior are vulnerable to a stack-based buffer overflow while processing project files, which may allow an attacker to execute arbitrary code. | 28/12/2021 |
| CVE-2021-43554 | ALTO7.8 | FATEK WinProladder Versions 3.30_24518 and prior are vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code. | 28/12/2021 |
| CVE-2021-38442 | ALTO7.8 | FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in a heap-corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. | 18/10/2021 |
| CVE-2021-38440 | BAJO3.3 | FATEK Automation WinProladder versions 3.30 and prior is vulnerable to an out-of-bounds read, which may allow an attacker to read unauthorized information. | 18/10/2021 |
| CVE-2021-38438 | ALTO7.8 | A use after free vulnerability in FATEK Automation WinProladder versions 3.30 and prior may be exploited when a valid user opens a malformed project file, which may allow arbitrary code execution. | 18/10/2021 |
| CVE-2021-38436 | ALTO7.8 | FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in a memory-corruption condition. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process. | 18/10/2021 |
| CVE-2021-38434 | ALTO7.8 | FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in an unexpected sign extension. An attacker could leverage this vulnerability to execute arbitrary code. | 18/10/2021 |
| CVE-2021-38430 | ALTO7.8 | FATEK Automation WinProladder versions 3.30 and prior proper validation of user-supplied data when parsing project files, which could result in a stack-based buffer overflow. An attacker could leverage this vulnerability to execute arbitrary code. | 18/10/2021 |
| CVE-2021-38426 | ALTO7.8 | FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code. | 18/10/2021 |
| CVE-2021-32992 | CRÍTICO9.8 | FATEK Automation WinProladder Versions 3.30 and prior do not properly restrict operations within the bounds of a memory buffer, which may allow an attacker to execute arbitrary code. | 29/06/2021 |
| CVE-2021-32990 | CRÍTICO9.8 | FATEK Automation WinProladder Versions 3.30 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code. | 29/06/2021 |
| CVE-2021-32988 | CRÍTICO9.8 | FATEK Automation WinProladder Versions 3.30 and prior are vulnerable to an out-of-bounds write, which may allow an attacker to execute arbitrary code. | 29/06/2021 |
| CVE-2021-27486 | ALTO7.8 | FATEK Automation WinProladder Versions 3.30 and prior is vulnerable to an integer underflow, which may cause an out-of-bounds write and allow an attacker to execute arbitrary code. | 12/04/2021 |
| CVE-2020-16234 | ALTO7.8 | In PLC WinProladder Version 3.28 and prior, a stack-based buffer overflow vulnerability can be exploited when a valid user opens a specially crafted file, which may allow an attacker to remotely execute arbitrary code. | 30/09/2020 |