CVE search
Every published CVE plus open-source advisories (NVD, OSV, GitHub), with CVSS, EPSS and whether it is being exploited in the wild (CISA KEV). Updated every few hours. Our scans match these against the technologies they detect.
Every published CVE plus open-source advisories (NVD, OSV, GitHub), with CVSS, EPSS and whether it is being exploited in the wild (CISA KEV). Updated every few hours. Our scans match these against the technologies they detect.
| CVE-2023-39226 | CRITIQUE9.8 | In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute arbitrary code through a single UDP packet. | 30/11/2023 |
| CVE-2023-34316 | ÉLEVÉE7.5 | An attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents. | 10/07/2023 |
| CVE-2023-30765 | CRITIQUE9.8 | Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation. | 10/07/2023 |
| CVE-2023-34347 | CRITIQUE9.8 |
Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.
| 10/07/2023 |
| CVE-2023-1145 | ÉLEVÉE7.8 |
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.
| 27/03/2023 |
| CVE-2023-1144 | ÉLEVÉE8.8 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation. | 27/03/2023 |
| CVE-2023-1143 | ÉLEVÉE8.8 | In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code. | 27/03/2023 |
| CVE-2023-1142 | CRITIQUE9.8 | In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation. | 27/03/2023 |
| CVE-2023-1141 | ÉLEVÉE8.8 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could result in remote code execution. | 27/03/2023 |
| CVE-2023-1140 | CRITIQUE9.8 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator. | 27/03/2023 |
| CVE-2023-1139 | ÉLEVÉE8.8 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which could allow deserialization of requests prior to authentication, resulting in remote code execution. | 27/03/2023 |
| CVE-2023-1138 | ÉLEVÉE7.5 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve Gateway configuration files to obtain plaintext credentials. | 27/03/2023 |
| CVE-2023-1137 | ÉLEVÉE8.8 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentials of administrator users, resulting in privilege escalation. | 27/03/2023 |
| CVE-2023-1136 | ÉLEVÉE7.5 | In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an unauthenticated attacker could generate a valid token, which would lead to authentication bypass. | 27/03/2023 |
| CVE-2023-1135 | ÉLEVÉE7.8 |
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could set incorrect directory permissions, which could result in local privilege escalation.
| 27/03/2023 |
| CVE-2023-1134 | ÉLEVÉE8.8 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges. | 27/03/2023 |
| CVE-2023-1133 | CRITIQUE9.8 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated attacker to remotely execute arbitrary co | 27/03/2023 |