Advantech WebAccess 8.4.2 and 8.4.4 allows XSS via the username column of the bwRoot.asp page of WADashboard. |
| 11/06/2021 |
| CVE-2021-27437 | 심각9.1 | The affected product allows attackers to obtain sensitive information from the WISE-PaaS dashboard. The system contains a hard-coded administrator username and password that can be used to query Grafana APIs. Authentication is not required for exploitation on the WISE-PaaS/RMM (versions prior to 9.0.1). | 07/05/2021 |
| CVE-2021-22669 | 높음8.8 | Incorrect permissions are set to default on the ‘Project Management’ page of WebAccess/SCADA portal of WebAccess/SCADA Versions 9.0.1 and prior, which may allow a low-privileged user to update an administrator’s password and login as an administrator to escalate privileges on the system. | 26/04/2021 |
| CVE-2021-27436 | 보통6.1 | WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user’s cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions. | 18/03/2021 |
| CVE-2020-13554 | 높음7.8 | An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege. | 03/03/2021 |
| CVE-2020-25161 | 높음8.8 | The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator. | 23/02/2021 |
| CVE-2020-13555 | 높음8.8 | An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In COM Server Application Privilege Escalation, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege. | 17/02/2021 |
| CVE-2020-13553 | 높음8.8 | An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege. | 17/02/2021 |
| CVE-2020-13552 | 높음8.8 | An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via multiple service executables in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYST | 17/02/2021 |
| CVE-2020-13551 | 높음8.8 | An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via PostgreSQL executable, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege. | 17/02/2021 |
| CVE-2020-13550 | 높음7.7 | A local file inclusion vulnerability exists in the installation functionality of Advantech WebAccess/SCADA 9.0.1. A specially crafted application can lead to information disclosure. An attacker can send an authenticated HTTP request to trigger this vulnerability. | 17/02/2021 |
| CVE-2021-22658 | 심각9.8 | Advantech iView versions prior to v5.7.03.6112 are vulnerable to a SQL injection, which may allow an attacker to escalate privileges to 'Administrator'. | 11/02/2021 |
| CVE-2021-22656 | 높음7.5 | Advantech iView versions prior to v5.7.03.6112 are vulnerable to directory traversal, which may allow an attacker to read sensitive files. | 11/02/2021 |
| CVE-2021-22654 | 높음7.5 | Advantech iView versions prior to v5.7.03.6112 are vulnerable to a SQL injection, which may allow an unauthorized attacker to disclose information. | 11/02/2021 |
| CVE-2021-22652 | 심각9.8 | Access to the Advantech iView versions prior to v5.7.03.6112 configuration are missing authentication, which may allow an unauthorized attacker to change the configuration and obtain code execution. | 11/02/2021 |
| CVE-2020-25157 | 높음7.5 | The R-SeeNet webpage (1.5.1 through 2.4.10) suffers from SQL injection, which allows a remote attacker to invoke queries on the database and retrieve sensitive information. | 20/10/2020 |
| CVE-2020-16202 | 높음7.8 | WebAccess Node (All versions prior to 9.0.1) has incorrect permissions set for resources used by specific services, which may allow code execution with system privileges. | 22/09/2020 |