| 28/11/2023 |
| CVE-2023-29063 | 낮음2.4 | The FACSChorus workstation does not prevent physical access to its PCI express (PCIe) slots, which could allow a threat actor to insert a PCI card designed for memory capture. A threat actor can then isolate sensitive information such as a BitLocker encryption key from a dump of the workstation RAM during startup. | 28/11/2023 |
| CVE-2023-29062 | 낮음3.8 | The Operating System hosting the FACSChorus application is configured to allow transmission of hashed user credentials upon user action without adequately validating the identity of the requested resource. This is possible through the use of LLMNR, MBT-NS, or MDNS and will result in NTLMv2 hashes being sent to a malici | 28/11/2023 |
| CVE-2023-29061 | 보통5.2 | There is no BIOS password on the FACSChorus workstation. A threat actor with physical access to the workstation can potentially exploit this vulnerability to access the BIOS configuration and modify the drive boot order and BIOS pre-boot authentication. | 28/11/2023 |
| CVE-2023-29060 | 보통5.7 | The FACSChorus workstation operating system does not restrict what devices can interact with its USB ports. If exploited, a threat actor with physical access to the workstation could gain access to system information and potentially exfiltrate data. | 28/11/2023 |
| CVE-2023-30565 | 낮음3.5 | An insecure connection between Systems Manager and CQI Reporter application could expose infusion data to an attacker. | 13/07/2023 |
| CVE-2023-30564 | 보통6.9 | Alaris Systems Manager does not perform input validation during the Device Import Function. | 13/07/2023 |
| CVE-2023-30563 | 높음8.2 | A malicious file could be uploaded into a System Manager User Import Function resulting in a hijacked session. | 13/07/2023 |
| CVE-2023-30562 | 보통6.7 | A GRE dataset file within Systems Manager can be tampered with and distributed to PCUs.
| 13/07/2023 |
| CVE-2022-47376 | 높음7.3 | The Alaris Infusion Central software, versions 1.1 to 1.3.2, may contain a recoverable password after the installation. No patient health data is stored in the database, although some site installations may choose to store personal data. | 13/06/2023 |
| CVE-2022-30277 | 보통5.7 | BD Synapsys™, versions 4.20, 4.20 SR1, and 4.30, contain an insufficient session expiration vulnerability. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information (ePHI), protected health information (PHI) and personally identifiable i | 02/06/2022 |
| CVE-2020-25165 | 높음7.5 | BD Alaris PC Unit, Model 8015, Versions 9.33.1 and earlier and BD Alaris Systems Manager, Versions 4.33 and earlier The affected products are vulnerable to a network session authentication vulnerability within the authentication process between specified versions of the BD Alaris PC Unit and the BD Alaris Systems Manag | 13/11/2020 |
| CVE-2019-13517 | 높음8.8 | In Pyxis ES Versions 1.3.4 through to 1.6.1 and Pyxis Enterprise Server, with Windows Server Versions 4.4 through 4.12, a vulnerability has been identified where existing access privileges are not restricted in coordination with the expiration of access based on active directory user account changes when the device is | 06/09/2019 |
| CVE-2018-10595 | 보통6.3 | A vulnerability in ReadA version 1.1.0.2 and previous allows an authorized user with access to a privileged account on a BD Kiestra system (Kiestra TLA, Kiestra WCA, and InoqulA+ specimen processor) to issue SQL commands, which may result in loss or corruption of data. | 24/05/2018 |
| CVE-2018-10593 | 보통5.6 | A vulnerability in DB Manager version 3.0.1.0 and previous and PerformA version 3.0.0.0 and previous allows an authorized user with access to a privileged account on a BD Kiestra system (Kiestra TLA, Kiestra WCA, and InoqulA+ specimen processor) to issue SQL commands, which may result in data corruption. | 24/05/2018 |
| CVE-2017-6022 | 심각9.8 | A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limit | 30/06/2017 |
| CVE-2016-9355 | 보통5.3 | An issue was discovered in Becton, Dickinson and Company (BD) Alaris 8015 Point of Care (PC) unit, Version 9.5 and prior versions, and Version 9.7. An unauthorized user with physical access to an Alaris 8015 PC unit may be able to obtain unencrypted wireless network authentication credentials and other sensitive techni | 13/02/2017 |
| CVE-2016-8375 | 보통4.9 | An issue was discovered in Becton, Dickinson and Company (BD) Alaris 8015 Point of Care (PC) unit, Version 9.5 and prior versions, and Version 9.7, and 8000 PC unit. An unauthorized user with physical access to an affected Alaris PC unit may be able to obtain unencrypted wireless network authentication credentials and | 13/02/2017 |