CVE search
Every published CVE plus open-source advisories (NVD, OSV, GitHub), with CVSS, EPSS and whether it is being exploited in the wild (CISA KEV). Updated every few hours. Our scans match these against the technologies they detect.
Every published CVE plus open-source advisories (NVD, OSV, GitHub), with CVSS, EPSS and whether it is being exploited in the wild (CISA KEV). Updated every few hours. Our scans match these against the technologies they detect.
| 24/07/2014 |
| CVE-2014-4684 | 中危6.0 | The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433. | 24/07/2014 |
| CVE-2014-4683 | 中危4.9 | The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request. | 24/07/2014 |
| CVE-2014-4682 | 中危5.0 | The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request. | 24/07/2014 |
| CVE-2014-2733 | 中危5.0 | Siemens SINEMA Server before 12 SP1 allows remote attackers to cause a denial of service (web-interface outage) via crafted HTTP requests to port (1) 4999 or (2) 80. | 19/04/2014 |
| CVE-2014-2732 | 中危5.0 | Multiple directory traversal vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to access arbitrary files via HTTP traffic to port (1) 4999 or (2) 80. | 19/04/2014 |
| CVE-2014-2731 | 严重9.3 | Multiple unspecified vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to execute arbitrary code via HTTP traffic to port (1) 4999 or (2) 80. | 19/04/2014 |
| CVE-2014-0160KEV | 高危7.5 | The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c | 07/04/2014 |
| CVE-2014-1699 | 中危5.0 | Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service (monitoring-service outage) via malformed HTTP requests to port 4999. | 07/02/2014 |
| CVE-2014-1698 | 中危5.0 | Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999. | 07/02/2014 |
| CVE-2014-1697 | 高危7.5 | The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999. | 07/02/2014 |
| CVE-2014-1696 | 中危5.0 | Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack. | 07/02/2014 |
| CVE-2013-6840 | 中危6.9 | Siemens COMOS before 9.2.0.8.1, 10.0 before 10.0.3.1.40, and 10.1 before 10.1.0.0.2 allows local users to gain database privileges via unspecified vectors. | 10/12/2013 |
| CVE-2013-4943 | 高危7.2 | The client application in Siemens COMOS before 9.1 Update 458, 9.2 before 9.2.0.6.37, and 10.0 before 10.0.3.0.19 allows local users to gain privileges and bypass intended database-operation restrictions by leveraging COMOS project access. | 09/08/2013 |
| CVE-2013-4912 | 中危5.8 | Open redirect vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging improper configuration of SIMATIC HMI panels by the WinCC product. | 01/08/2013 |
| CVE-2013-4911 | 中危6.8 | Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to hijack the authentication of unspecified victims by leveraging improper configuration of SIMATIC HMI panels by the WinCC product. | 01/08/2013 |
| CVE-2013-4781 | 严重10.0 | core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to execute arbitrary commands via unspecified vectors. | 18/07/2013 |
| CVE-2013-4780 | 高危7.8 | core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to read arbitrary files via unspecified vectors. | 18/07/2013 |