CVE search
Every published CVE plus open-source advisories (NVD, OSV, GitHub), with CVSS, EPSS and whether it is being exploited in the wild (CISA KEV). Updated every few hours. Our scans match these against the technologies they detect.
Every published CVE plus open-source advisories (NVD, OSV, GitHub), with CVSS, EPSS and whether it is being exploited in the wild (CISA KEV). Updated every few hours. Our scans match these against the technologies they detect.
| 18/09/2020 |
| CVE-2020-16198 | MEDIUM6.3 | When an attacker claims to have a given identity,
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
does not prove or insufficiently proves the claim is correct. | 18/09/2020 |
| CVE-2020-14525 | LOW3.5 | Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input
before it is placed in output used as a webpage that is served to other
users. | 18/09/2020 |
| CVE-2020-14506 | MEDIUM4.3 | Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly. | 18/09/2020 |
| CVE-2020-16224 | MEDIUM6.5 | In Patient Information Center iX (PICiX) Versions C.02, C.03, the
software parses a formatted message or structure but does not handle or
incorrectly handles a length field that is inconsistent with the actual
length of the associated data, causing the application on the
surveillance station to restart. | 11/09/2020 |
| CVE-2020-16220 | MEDIUM4.3 | In Patient Information Center iX (PICiX) Versions C.02, C.03,
PerformanceBridge Focal Point Version A.01, the product receives input
that is expected to be well-formed (i.e., to comply with a certain
syntax) but it does not validate or incorrectly validates that the input
complies with the syntax, causing the certi | 11/09/2020 |
| CVE-2020-16216 | MEDIUM6.5 | In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750,
MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior,
the product receives input or data but does not validate or incorrectly
validates that the input has the properties required to process the data
safely and correctly, which ca | 11/09/2020 |
| CVE-2020-16212 | MEDIUM6.8 | In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could all | 11/09/2020 |
| CVE-2020-16228 | MEDIUM6.4 | In Patient Information Center iX (PICiX) Versions C.02 and C.03,
PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors
MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and
prior, the software does not check or incorrectly checks the revocation
status of a certificate, which may cause | 11/09/2020 |
| CVE-2020-16222 | HIGH8.8 | In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and
PerformanceBridge Focal Point Version A.01, when an actor claims to have
a given identity, the software does not prove or insufficiently proves
the claim is correct. | 11/09/2020 |
| CVE-2020-16218 | LOW3.5 | In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software does not neutralize or incorrectly neutralizes
user-controllable input before it is placed in output that is then used
as a webpage and served to other users. Successful exploitation could
lead to unauthorized access to patient data vi | 11/09/2020 |
| CVE-2020-16214 | MEDIUM5.0 | In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software saves user-provided information into a comma-separated value
(CSV) file, but it does not neutralize or incorrectly neutralizes
special elements that could be interpreted as a command when the file is
opened by spreadsheet software. | 11/09/2020 |
| CVE-2020-14518 | MEDIUM5.3 | Philips DreamMapper, Version 2.24 and prior. Information written to log files can give guidance to a potential attacker. | 21/08/2020 |
| CVE-2020-7360 | HIGH7.3 | An Uncontrolled Search Path Element (CWE-427) vulnerability in SmartControl version 4.3.15 and versions released before April 15, 2020 may allow an authenticated user to escalate privileges by placing a specially crafted DLL file in the search path. This issue was fixed in version 1.0.7, which was released after April | 13/08/2020 |
| CVE-2020-12023 | MEDIUM4.5 | Philips IntelliBridge Enterprise (IBE), Versions B.12 and prior, IntelliBridge Enterprise system integration with SureSigns (VS4), EarlyVue (VS30) and IntelliVue Guardian (IGS). Unencrypted user credentials received in the IntelliBridge Enterprise (IBE) are logged within the transaction logs, which are secured behind t | 11/06/2020 |
| CVE-2019-13557 | MEDIUM5.3 | In Tasy EMR, Tasy WebPortal Versions 3.02.1757 and prior, there is an information exposure vulnerability which may allow a remote attacker to access system and configuration information. | 08/11/2019 |
| CVE-2019-13546 | MEDIUM6.8 | In IntelliSpace Perinatal, Versions K and prior, a vulnerability within the IntelliSpace Perinatal application environment could enable an unauthorized attacker with physical access to a locked application screen, or an authorized remote desktop session host application user to break-out from the containment of the app | 25/10/2019 |
| CVE-2019-6562 | MEDIUM5.4 | In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users. | 01/05/2019 |